Chillers | Unichiller • Minichiller
Many applications depend on a reliable source of cooling. Circulating chillers in the Unichiller range offer an ideal solution for environmentally friendly and economical cooling in laboratory and industry. There are over 50 air and water cooled models to choose from, with cooling powers from 0,3 to 50 kW. Efficient energy management in all Huber chillers ensures low operating costs and reduced usage of valuable fresh water. Huber circulating chillers are a resource saving solution with a quick return on investment. |
![]() |
View options: Disable variants Enable miniature pictures
HUBER Order No. |
HUBER Model |
Temp. range °C |
Temp. stability °C |
Heating capacity kW |
Cooling capacity kW |
Pump performance
|
Fill vol. Litres |
Bath opening/ bath depth WxD / BD mm |
Temp. control mode |
Mains voltage |
Model series |
Eco | ||||||||
![]() |
||||||||||||||||||||
3000.0001.99 | DC30 | -30...50 | -- | -- | 0,2 kW @ 15°C |
|
-- | -- | ext. | 230V 1~ 50Hz | DC |
![]() |
||||||||
3001.0001.99 | DC31 | -30...50 | -- | -- | 0,4 kW @ 15°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | DC |
![]() |
||||||||
3002.0001.99 | DC32 | -30...50 | -- | -- | 0,6 kW @ 15°C |
|
-- | -- | ext. | 230V 1~ 50Hz | DC |
![]() |
||||||||
![]() |
||||||||||||||||||||
3011.0008.99 | HTS PS1 | (5)...(80) | -- | -- | 0,6520 |
|
-- | -- | ext. | 230V 1~ 50/60Hz | Chiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3006.0105.98 | Minichiller 280 OLÉ | -5...40 | ±1 | -- | 0,28 kW @ 15°C |
|
2 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0089.98 | Minichiller 300 OLÉ | -20...40 (80 ) | ±0,5 | -- | 0,3 kW @ 15°C |
|
1,4 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0091.98 | Minichiller 300-H OLÉ | -20...100 | ±0,2 | 1 | 0,3 kW @ 15°C |
|
1,4 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0090.98 | Minichiller 300w OLÉ | -20...40 (80 ) | ±0,5 | -- | 0,3 kW @ 15°C |
|
1,4 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0092.98 | Minichiller 300w-H OLÉ | -20...100 | ±0,2 | 1 | 0,3 kW @ 15°C |
|
1,4 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0098.98 | Minichiller 600 OLÉ | -20...40 | ±0,5 | -- | 0,6 kW @ 15°C |
|
2,8 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0099.98 | Minichiller 600-H OLÉ | -20...100 | ±0,5 | 2 | 0,6 kW @ 15°C |
|
2,8 | -- | ext. | 230V 1~ 50/60Hz | Minichiller |
![]() |
||||||||
3006.0121.98 | Minichiller 900w OLÉ | -25...40 | ±0,5 | -- | 0,9 kW @ 15°C |
|
2,8 | -- | ext. | 230V 1~ 50Hz | Minichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3033.0007.99 | RotaCool | -10...40 | ±1 | -- | 0,42 kW @ 15°C |
|
1,5 | -- | ext. | 230V 1~ 50/60Hz | RotaCool |
![]() |
||||||||
![]() |
||||||||||||||||||||
3005.0043.99 | TC100 | -100...40 | -- | -- | 0,16 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3005.0044.99 | TC100E | -100...40 | ±0,5 | -- | 0,16 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3005.0046.99 | TC100E-F | -100...40 | ±0,5 | -- | 0,16 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3005.0045.99 | TC100-F | -100...40 | -- | -- | 0,16 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3003.0001.99 | TC45 | -45...100 | -- | -- | 0,24 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3003.0002.99 | TC45E | -45...100 | ±0,5 | -- | 0,24 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3003.0004.99 | TC45E-F | -45...100 | ±0,5 | -- | 0,24 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3003.0003.99 | TC45-F | -45...100 | -- | -- | 0,24 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3004.0001.99 | TC50 | -50...50 | -- | -- | 0,3 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3004.0002.99 | TC50E | -50...50 | ±0,5 | -- | 0,3 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3004.0004.99 | TC50E-F | -50...50 | ±0,5 | -- | 0,3 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
3004.0003.99 | TC50-F | -50...50 | -- | -- | 0,3 kW @ 0°C |
|
-- | -- | ext. | 230V 1~ 50/60Hz | TC |
![]() |
||||||||
![]() |
||||||||||||||||||||
3012.0189.01 | Unichiller 007 | -20...40 | ±0,5 | -- | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0120.98 | Unichiller 007 OLÉ | -20...40 | ±0,5 | -- | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0190.01 | Unichiller 007-H | -20...100 | ±0,2 | 2 | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0122.98 | Unichiller 007-H OLÉ | -20...100 | ±0,2 | 2 | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0215.01 | Unichiller 007w | -20...40 | ±0,5 | -- | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0216.01 | Unichiller 007w-H | -20...100 | ±0,5 | 2 | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0191.01 | Unichiller 010 | -20...40 | ±0,5 | -- | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0124.98 | Unichiller 010 OLÉ | -20...40 | ±0,5 | -- | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0192.01 | Unichiller 010-H | -20...100 | ±0,2 | 2 | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0127.98 | Unichiller 010-H OLÉ | -20...100 | ±0,2 | 2 | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0219.01 | Unichiller 010w | -20...40 | ±0,5 | -- | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3009.0145.01 | Unichiller 012 | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0090.98 | Unichiller 012 OLÉ | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0146.01 | Unichiller 012-H | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0091.98 | Unichiller 012-H OLÉ | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0193.01 | Unichiller 012w | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0133.98 | Unichiller 012w OLÉ | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0194.01 | Unichiller 012w-H | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0134.98 | Unichiller 012w-H OLÉ | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0147.01 | Unichiller 015 | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0094.98 | Unichiller 015 OLÉ | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0148.01 | Unichiller 015-H | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0095.98 | Unichiller 015-H OLÉ | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0195.01 | Unichiller 015w | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0137.98 | Unichiller 015w OLÉ | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0196.01 | Unichiller 015w-H | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0138.98 | Unichiller 015w-H OLÉ | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3013.0001.01 | Unichiller 017T | -10...40 | ±0,5 | -- | 1,7 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3013.0004.01 | Unichiller 017T-H | -10...100 | ±0,2 | 2 | 1,7 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3024.0021.01 | Unichiller 017Tw | -10...40 | ±0,5 | -- | 1,7 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3024.0023.01 | Unichiller 017Tw-H | -10...100 | ±0,2 | 2 | 1,7 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3013.0002.01 | Unichiller 020T | -20...40 | ±0,5 | -- | 2 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3013.0005.01 | Unichiller 020T-H | -20...100 | ±0,2 | 2 | 2 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3024.0025.01 | Unichiller 020Tw | -20...40 | ±0,5 | -- | 2 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3024.0028.01 | Unichiller 020Tw-H | -20...100 | ±0,2 | 2 | 2 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3010.0081.01 | Unichiller 022 | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0050.98 | Unichiller 022 OLÉ | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0082.01 | Unichiller 022-H | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0051.98 | Unichiller 022-H OLÉ | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0149.01 | Unichiller 022w | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0098.98 | Unichiller 022w OLÉ | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0150.01 | Unichiller 022w-H | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0099.98 | Unichiller 022w-H OLÉ | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0083.01 | Unichiller 025 | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0054.98 | Unichiller 025 OLÉ | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0084.01 | Unichiller 025-H | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0055.98 | Unichiller 025-H OLÉ | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3013.0003.01 | Unichiller 025T | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3013.0006.01 | Unichiller 025T-H | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3024.0031.01 | Unichiller 025Tw | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3024.0035.01 | Unichiller 025Tw-H | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
2,5 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3009.0151.01 | Unichiller 025w | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0102.98 | Unichiller 025w OLÉ | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0152.01 | Unichiller 025w-H | -10...100 | ±0,5 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0103.98 | Unichiller 025w-H OLÉ | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3025.0022.01 | Unichiller 030Tw | -20...40 | ±0,5 | -- | 3 kW @ 15°C |
|
2,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3025.0025.01 | Unichiller 030Tw-H | -20...100 | ±0,2 | 2 | 3 kW @ 15°C |
|
2,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3014.0001.01 | Unichiller 040T | -10...40 | ±0,5 | -- | 4 kW @ 15°C |
|
3,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3014.0003.01 | Unichiller 040T-H | -10...100 | ±0,2 | 2 | 4 kW @ 15°C |
|
3,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3025.0033.01 | Unichiller 040Tw | -10...40 | ±0,5 | -- | 4 kW @ 15°C |
|
2,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3025.0035.01 | Unichiller 040Tw-H | -10...100 | ±0,2 | 2 | 4 kW @ 15°C |
|
2,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3014.0002.01 | Unichiller 045T | -20...40 | ±0,5 | -- | 4,5 kW @ 15°C |
|
3,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3014.0004.01 | Unichiller 045T-H | -20...100 | ±0,2 | 2 | 4,5 kW @ 15°C |
|
3,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3038.0001.01 | Unichiller 050 | -20...40 | ±0,5 | -- | 4,2 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0003.01 | Unichiller 050-H | -20...100 | ±0,2 | 2 | 4,2 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0001.01 | Unichiller 050w | -20...40 | ±0,5 | -- | 4,2 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0002.01 | Unichiller 050w-H | -20...100 | ±0,2 | 2 | 4,2 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3015.0042.01 | Unichiller 055T | -10...40 | ±0,5 | -- | 5,5 kW @ 15°C |
|
5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3015.0043.01 | Unichiller 055T-H | -10...100 | ±0,2 | 2 | 5,5 kW @ 15°C |
|
5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3026.0001.01 | Unichiller 055Tw | -10...40 | ±0,5 | -- | 5,5 kW @ 15°C |
|
5,9 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3026.0005.01 | Unichiller 055Tw-H | -10...100 | ±0,2 | 2 | 5,5 kW @ 15°C |
|
5,9 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3015.0044.01 | Unichiller 060T | -20...40 | ±0,5 | -- | 6 kW @ 15°C |
|
5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3015.0045.01 | Unichiller 060T-H | -20...100 | ±0,2 | 2 | 6 kW @ 15°C |
|
5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3026.0002.01 | Unichiller 060Tw | -20...40 | ±0,5 | -- | 6 kW @ 15°C |
|
5,9 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3026.0006.01 | Unichiller 060Tw-H | -20...100 | ±0,2 | 2 | 6 kW @ 15°C |
|
5,9 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3038.0018.01 | Unichiller 075 | -20...40 | ±0,5 | -- | 6,1 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0020.01 | Unichiller 075-H | -20...100 | ±0,2 | 2 | 6,1 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0009.01 | Unichiller 075w | -20...40 | ±0,5 | -- | 6,1 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0010.01 | Unichiller 075w-H | -20...100 | ±0,2 | 2 | 6,1 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3016.0001.01 | Unichiller 080T | -10...40 | ±0,5 | -- | 8 kW @ 15°C |
|
5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3016.0002.01 | Unichiller 080T-H | -10...100 | ±0,2 | 2 | 8 kW @ 15°C |
|
5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3026.0003.01 | Unichiller 080Tw | -10...40 | ±0,5 | -- | 8 kW @ 15°C |
|
5,9 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3026.0007.01 | Unichiller 080Tw-H | -10...100 | ±0,2 | 2 | 8 kW @ 15°C |
|
5,9 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3038.0035.01 | Unichiller 100 | -20...40 | ±0,5 | -- | 8,6 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0036.01 | Unichiller 100-H | -20...100 | ±0,2 | 2 | 8,6 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3017.0001.01 | Unichiller 100T | -20...40 | ±0,5 | -- | 10 kW @ 15°C |
|
8,36 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3017.0003.01 | Unichiller 100T-H | -20...100 | ±0,2 | 2 | 10 kW @ 15°C |
|
8,36 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0001.01 | Unichiller 100Tw | -20...40 | ±0,5 | -- | 10 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0006.01 | Unichiller 100Tw-H | -20...100 | ±0,2 | 2 | 10 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3040.0017.01 | Unichiller 100w | -20...40 | ±0,5 | -- | 8,6 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0018.01 | Unichiller 100w-H | -20...100 | ±0,2 | 2 | 8,6 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3017.0002.01 | Unichiller 110T | -10...40 | ±0,5 | -- | 11 kW @ 15°C |
|
8,36 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3017.0004.01 | Unichiller 110T-H | -10...100 | ±0,2 | 2 | 11 kW @ 15°C |
|
8,36 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0002.01 | Unichiller 110Tw | -10...40 | ±0,5 | -- | 11 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0007.01 | Unichiller 110Tw-H | -10...100 | ±0,2 | 2 | 11 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3018.0012.01 | Unichiller 130T | -10...40 | ±0,5 | -- | 13 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3018.0003.01 | Unichiller 130T-H | -10...100 | ±0,2 | 2 | 13 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0003.01 | Unichiller 130Tw | -10...40 | ±0,5 | -- | 13 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0008.01 | Unichiller 130Tw-H | -10...100 | ±0,2 | 2 | 13 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3019.0020.01 | Unichiller 150T | -20...40 | ±0,5 | -- | 15 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3019.0021.01 | Unichiller 150T-H | -20...100 | ±0,2 | 2 | 15 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0001.01 | Unichiller 150Tw | -20...40 | ±0,5 | -- | 15 kW @ 15°C |
|
12,7 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0007.01 | Unichiller 150Tw-H | -20...100 | ±0,2 | 2 | 15 kW @ 15°C |
|
12,7 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3018.0013.01 | Unichiller 160T | -10...40 | ±0,5 | -- | 16 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3018.0004.01 | Unichiller 160T-H | -10...100 | ±0,2 | 2 | 16 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0004.01 | Unichiller 160Tw | -10...40 | ±0,5 | -- | 16 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3027.0009.01 | Unichiller 160Tw-H | -10...100 | ±0,2 | 2 | 16 kW @ 15°C |
|
6,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3019.0026.01 | Unichiller 200T | -10...40 | ±0,5 | -- | 20 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3019.0004.01 | Unichiller 200T-H | -10...100 | ±0,2 | 2 | 20 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0002.01 | Unichiller 200Tw | -10...40 | ±0,5 | -- | 20 kW @ 15°C |
|
12,7 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0008.01 | Unichiller 200Tw-H | -10...100 | ±0,2 | 2 | 20 kW @ 15°C |
|
12,7 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0001.01 | Unichiller 210T | -20...40 | ±0,5 | -- | 21 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0005.01 | Unichiller 210T-H | -20...100 | ±0,2 | 2 | 21 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0003.01 | Unichiller 210Tw | -20...40 | ±0,5 | -- | 21 kW @ 15°C |
|
13 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0009.01 | Unichiller 210Tw-H | -20...100 | ±0,2 | 2 | 21 kW @ 15°C |
|
13 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0002.01 | Unichiller 250T | -10...40 | ±0,5 | -- | 25 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0006.01 | Unichiller 250T-H | -10...100 | ±0,2 | 2 | 25 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0004.01 | Unichiller 250Tw | -10...40 | ±0,5 | -- | 25 kW @ 15°C |
|
5,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0010.01 | Unichiller 250Tw-H | -10...100 | ±0,2 | 2 | 25 kW @ 15°C |
|
5,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0003.01 | Unichiller 260T | -20...40 | ±0,5 | -- | 26 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0007.01 | Unichiller 260T-H | -20...100 | ±0,2 | 2 | 26 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0005.01 | Unichiller 260Tw | -20...40 | ±0,5 | -- | 26 kW @ 15°C |
|
12,3 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3028.0011.01 | Unichiller 260Tw-H | -20...100 | ±0,2 | 2 | 26 kW @ 15°C |
|
12,3 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0004.01 | Unichiller 300T | -10...40 | ±0,5 | -- | 30 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3020.0008.01 | Unichiller 300T-H | -10...100 | ±0,2 | 2 | 30 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3029.0001.01 | Unichiller 300Tw | -10...40 | ±0,5 | -- | 30 kW @ 15°C |
|
9,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3029.0003.01 | Unichiller 300Tw-H | -10...100 | ±0,2 | 2 | 30 kW @ 15°C |
|
9,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3021.0001.01 | Unichiller 400T | -10...40 | ±0,5 | -- | 40 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3021.0002.01 | Unichiller 400T-H | -10...100 | ±0,2 | 2 | 40 kW @ 15°C |
|
14 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3029.0002.01 | Unichiller 400Tw | -10...40 | ±0,5 | -- | 40 kW @ 15°C |
|
9,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3029.0004.01 | Unichiller 400Tw-H | -10...100 | ±0,2 | 2 | 40 kW @ 15°C |
|
9,5 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3030.0001.01 | Unichiller 500Tw | -10...40 | ±0,5 | -- | 50 kW @ 15°C |
|
17 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3030.0002.01 | Unichiller 500Tw-H | -10...100 | ±0,2 | 2 | 50 kW @ 15°C |
|
17 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
![]() |
||||||||||||||||||||
3012.0169.01 | Unichiller P007 | -20...40 | ±0,5 | -- | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0161.98 | Unichiller P007 OLÉ | -20...40 | ±0,5 | -- | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0170.01 | Unichiller P007-H | -20...100 | ±0,2 | 2 | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0162.98 | Unichiller P007-H OLÉ | -20...100 | ±0,5 | 2 | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0217.01 | Unichiller P007w | -20...40 | ±0,5 | -- | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0218.01 | Unichiller P007w-H | -20...100 | ±0,5 | 2 | 0,7 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0171.01 | Unichiller P010 | -20...40 | ±0,5 | -- | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0163.98 | Unichiller P010 OLÉ | -20...40 | ±0,5 | -- | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0172.01 | Unichiller P010-H | -20...100 | ±0,2 | 2 | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0164.98 | Unichiller P010-H OLÉ | -20...100 | ±0,5 | 2 | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0220.01 | Unichiller P010w | -20...40 | ±0,5 | -- | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3012.0221.01 | Unichiller P010w-H | -20...100 | ±0,5 | 2 | 1 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50/60Hz | Unichiller |
![]() |
||||||||
3009.0123.01 | Unichiller P012 | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0115.98 | Unichiller P012 OLÉ | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0124.01 | Unichiller P012-H | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0116.98 | Unichiller P012-H OLÉ | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0173.01 | Unichiller P012w | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0165.98 | Unichiller P012w OLÉ | -20...40 | ±0,5 | -- | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0174.01 | Unichiller P012w-H | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0166.98 | Unichiller P012w-H OLÉ | -20...100 | ±0,2 | 2 | 1,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0125.01 | Unichiller P015 | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0117.98 | Unichiller P015 OLÉ | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0126.01 | Unichiller P015-H | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0118.98 | Unichiller P015-H OLÉ | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0175.01 | Unichiller P015w | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0167.98 | Unichiller P015w OLÉ | -20...40 | ±0,5 | -- | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0176.01 | Unichiller P015w-H | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3012.0168.98 | Unichiller P015w-H OLÉ | -20...100 | ±0,2 | 2 | 1,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0068.01 | Unichiller P022 | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0064.98 | Unichiller P022 OLÉ | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0069.01 | Unichiller P022-H | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0065.98 | Unichiller P022-H OLÉ | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0127.01 | Unichiller P022w | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0119.98 | Unichiller P022w OLÉ | -10...40 | ±0,5 | -- | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0128.01 | Unichiller P022w-H | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0120.98 | Unichiller P022w-H OLÉ | -10...100 | ±0,2 | 2 | 2,2 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0070.01 | Unichiller P025 | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0066.98 | Unichiller P025 OLÉ | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0071.01 | Unichiller P025-H | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3010.0067.98 | Unichiller P025-H OLÉ | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0129.01 | Unichiller P025w | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0121.98 | Unichiller P025w OLÉ | -10...40 | ±0,5 | -- | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0130.01 | Unichiller P025w-H | -10...100 | ±0,5 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3009.0122.98 | Unichiller P025w-H OLÉ | -10...100 | ±0,2 | 2 | 2,5 kW @ 15°C |
|
3,8 | -- | ext. | 230V 1~ 50Hz | Unichiller |
![]() |
||||||||
3038.0004.01 | Unichiller P050 | -20...40 | ±0,5 | -- | 3,4 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0005.01 | Unichiller P050-H | -20...100 | ±0,2 | 2 | 3,4 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0003.01 | Unichiller P050w | -20...40 | ±0,5 | -- | 3,4 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0004.01 | Unichiller P050w-H | -20...100 | ±0,2 | 2 | 3,4 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0021.01 | Unichiller P075 | -20...40 | ±0,5 | -- | 5,3 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0022.01 | Unichiller P075-H | -20...100 | ±0,2 | 2 | 5,3 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0011.01 | Unichiller P075w | -20...40 | ±0,5 | -- | 5,3 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0012.01 | Unichiller P075w-H | -20...100 | ±0,2 | 2 | 5,3 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0037.01 | Unichiller P100 | -20...40 | ±0,5 | -- | 7,8 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3038.0038.01 | Unichiller P100-H | -20...100 | ±0,2 | 2 | 7,8 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0019.01 | Unichiller P100w | -20...40 | ±0,5 | -- | 7,8 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||
3040.0020.01 | Unichiller P100w-H | -20...100 | ±0,2 | 2 | 7,8 kW @ 0°C |
|
18 | -- | ext. | 400V 3~ 50Hz * | Unichiller |
![]() |
||||||||